4.5kW Battery Charger

4.5 kW Constant Voltage Regulated Cum Emergency Battery Charger For LHB Ac Coaches
Specification No. RDSO/PE/SPEC/AC/0183-2018 (Rev-1) & RDSO/PE/SPEC/AC/0183-2018 (Rev-2)
Description :
- Naturally cooled, IGBT/SiC-based, DSP-controlled Constant Voltage Regulated cum Emergency Battery Charger.
- Equipped with output current and voltage limiting features.
- Suitable for underslung mounting on LHB coaches of Indian Railways.
- Integrates a separate Emergency Battery Charger (EBC) to feed the coach if the main RBC path fails.
- Operates on a nominal input 3-phase, 4-wire supply of 415 Volts ±15%, 50 Hz ±3%.
Technical Specifications :
| Ratings & I/O | |
| RBC Input | 415 V AC, 3-phase, 4-wire, 50 Hz; THD ≤ 10% |
| RBC Output | 110–135 V DC (keypad-settable); Total 35 A max; Battery charge current 10–15 A (settable) |
| Battery Type | 70/120 Ah lead-acid (flooded or VRLA) banks |
| EBC Input | 240 V AC single-phase, 50 Hz |
| EBC Output | 110 V ±5% DC, 22 A, up to 2.5 kW |
| Operating Modes | |
| Normal | RBC feeds 4.5 kW; EBC on standby |
| Emergency | If RBC fails, EBC auto-activates to feed 2.5 kW at 110 V DC; “Emergency Mode ON” LED |
| Regulation, Efficiency & Ripple | |
| Output Regulation | 122 ±2% V during normal charging across input/load range |
| Efficiency | RBC ≥85% (½-load), ≥92% (full-load); EBC ≥90% (full-load) |
| Ripple (r.m.s.) | RBC: Voltage ≤2%, Current ≤3%; EBC: Voltage ≤2% at full load |
| Environmental & Mechanical | |
| Ambient Conditions | −5 °C to +55 °C; RH up to 98%; dusty/coastal; vibration IEC 61373 (≈3 g); altitude ≤1200 m |
| Enclosure | IP-65 SS-304, 2.0 mm cubicle; natural cooling; under-slung mounting |
| Dimensions | L: 900 mm (max); W: 600 mm (max); H: 650 mm (max); Hole CTC: L 850±0.8, W 300±0.5 |
| Weight | ≤120 kg |
| Protections | |
| RBC Input | O/V–U/V trip: 480 ±5 V / 300 ±5 V; withstand 510 V AC for 2 min; auto-reset |
| RBC Output | O/V trip: 136 ±2 V; Current limit: 10–15 A battery (settable), 35 A total; overload 42 A |
| EBC Protection | Input O/V & U/V: 240 V ±15%; Output current limit: 24 A |
| General Protection | Reverse-polarity, short-circuit, earth-leakage >≈30 mA; galvanic isolation; IP65 protection |
| Indications & Diagnostics | |
| LED Indications | R/Y/B, battery charging ON, single-phasing, ±earth-leakage, battery not healthy, emergency mode ON |
| Diagnostics | Logs ≥300 events with RTC; USB port download (FIFO, no deletion) |
| Construction Highlights | |
| Industrial-grade electronics; FR-4 PCBs; SS hardware; H-class HF transformer; SS-304/S2 or SS-304/L enclosure; 2× M10 earthing pads | |