7.5 KW Battery Charger For Narrow Gauge Coaches


7.5 KW Battery Charger For Narrow Gauge Coaches

Specification No. EDTS 416, REV-0

Description

Technical Specifications :

Type
Charger Type Constant Voltage
Input Voltage
Nominal Voltage 415 V AC, 3-phase, 3-wire system
Operating Range 415 V ±15%, 50 Hz ±3%
THD (Max) Voltage < 10%
Output (DC)
Type Fully insulated from coach body (+ and – sides)
Output Voltage 122 V ±2% DC
Output Current 60 A max
Battery Type & Rating 110 V, 300 Ah VRLA
Efficiency Greater than 97% at full load
Ripple Content <2% of set Voltage, <3% of set Current
Protections
O/P Over Voltage 136 VDC ±2 V
Output Current Limit 60 A max
AC O/V & U/V Protection Trips at 300 ±5 V / 480 ±5 V; auto-restart; withstands 510 V AC for 2 min
Self-reset Feature Auto restart if trip condition normalizes
Earth Leakage Trip provided for >≈30 mA on +ve/−ve lines
IP Protection IP-67 (dust and water ingress protection)
Short Circuit Trip provided
Reverse Polarity Protection in battery circuits
Overload 22 A for 1 minute
Isolation Galvanic isolation provided
Construction
Enclosure 2 mm thick SS-304/S2 or SS-304/L
Dimensions L: 700 mm, W: 407 mm, H: 470 mm
Mounting 660 × 240 mm
Weight < 150 kg