3-Phase Loco Primary Transformer


PRIMARY VOLTAGE TRANSFORMER FOR 3-PHASE ELECTRIC LOCOMOTIVES

Specification No. CLW/ES/3/0009, Alt. ‘C’

Description

Technical Specifications :

Parameter Value
Max. Voltage (Um) 36 kV
Ratio 25000 / 200
Rated Output / Burden 30 VA
Accuracy Class ±1% (80%–120% of rated burden)
Secondary Thermal Limiting Factor 1.0 A continuously
Voltage Factor 1.5 × Un / 30 sec
Primary Resistance ≥ 250 kΩ
Max Output 150 VA
Frequency 50 Hz
Class of Insulating Material E
Insulation Level 36/75/170 kV
Winding 1
Creepage Path ≥ 1090 mm