Precooling Unit & Charger


Constant Voltage & Constant Current Pre Cooling Unit and Battery Charger For SGAC Coaches

Specification No. RDSO/PE/SPEC/AC/TL/0053(REV ‘0’) August-2007

Description

Technical Specifications :

Input Voltage
Nominal Voltage 415 V AC 3 phase, 3 wired system
Operating Voltage Range 415 V ± 15% 3 phase AC, 50 Hz
Output Voltage
DC Output Voltage 100-150 V DC
Output Current DC 220 A
Operating Modes The unit shall be suitable to work either in constant voltage or constant current mode while charging the battery exclusively. When used for pre-cooling purposes, it shall operate in constant voltage mode.